Allgemeintoleranzen

     
 

General production tolerances applied at DOCERAM are according to DIN ISO 2768-1(c). If tighter tolerances are required, products will be customized.

 
     
 

Tabular 1, limit deviations for linear measures
(Limit deviations in mm for nominal sizes in mm)

 
Tolerance Class 0.5 ~ 3 > 3 ~ 6 > 6 ~ 30 > 30 ~ 120 > 120 ~ 400 > 400 ~ 1000 > 1000 ~ 2000 > 2000 ~ 4000

(fine)
± 0.05 ± 0.05 ± 0.1 ± 0.15 ± 0.2 ± 0.3 ± 0.5 -
m
(medium)
± 0.1 ± 0.1 ± 0.2 ± 0.3 ± 0.5 ± 0.8 ± 1.2 ± 2
c
(coarse)
± 0.15 ± 0.2 ± 0.5 ± 0.8 ± 1.2 ± 2 ± 3 ± 4
v
(very coarse)
- ± 0.5 ± 1 ± 1.5 ±2 .5 ± 4 ± 6 ± 8
     
 

Tabular 2, limit deviations for radius of curvatures and chamfer height
(Limit deviations in mm for nominal sizes in mm)

 
Tolerance Class 0.5 ~ 3 > 3 ~ 6 > 6
f (fine) ± 0.2 ± 0.5 ± 1
m (medium) ± 0.2 ± 0.5 ± 1
c (coarse) ± 0.4 ± 1 ± 2
v (very coarse) ± 0.4 ± 1 ± 2
     
 

Tabular 3, limit deviations of angle measures
(Limit deviations in units of angular measures for nominal sizes of the shorter angular side in mm)

 
 
Tolerance Class to 10 > 10 ~ 50 > 50 ~ 120 > 120 ~ 400 > 400
f (fine) ± 1° ± 30' ± 20' ± 10' ± 5'
m (medium) ± 1° ± 30' ± 20' ± 10' ± 5'
c (coarse) ± 1° 30' ± 1° ± 30' ± 15' ± 10'
v (very coarse) ± 3° ± 2° ± 1° ± 30' ± 20'
 
     

The limit deviations of the tolerance classes m and f of DIN ISO 2768-1 are identical with those of DIN 7168-1.

General tolerances for form and position applied at DOCERAM are 1% of total length. If tighter tolerances are required, product will be customized

Hoch

Print | Close 

©2003-2007 DOCERAM Ingenieurkeramik.